Pneumatic Valves
Solenoid, manual, check, flow-control and manifold valves.
Also searched as: solenoid valve5/2 valveair valveflow controlmanifold
-
2-way Proportional Flow Control Valve
Number of Ways: 2
-
20-Port PEX-B Manifold with 1/2 in. Brass Ball Valves
Ports: 20Valve Size: 1/2 in.
-
3 Port Air Operated Valve
Port Size Range: 3/8" to 2"Ports: 3
-
3 Way 2 Position Air Hand Valve
Number of Positions: 2Number of Ways: 3Port Size: 1/4" NPT
-
3-Valve Inline Manifold Assembly
Valves: 3
-
3-WAY MANIFOLD 14 IN IM
Inlet: 1/4 in.Ways: 3
-
3/4 in. x 1/2 in. PEX-B Barb Poly-Alloy 4-Port Closed Manifold
Inlet Size: 3/4 in.Outlet Size: 1/2 in.Ports: 4
-
3/4 in. x 1/2 in. PEX-B Barb Poly-Alloy 6-Port Open Manifold
Inlet: 3/4 in.Outlet: 1/2 in.Ports: 6
-
3/4 in. x 3/4 in. x (4) 1/2 in. CSST FIPT Stainless Steel Manifold
Inlet Size: 3/4 in.Outlet Size: 1/2 in.Outlets: 4
-
3/4" Pneumatic Actuated Ball Valve, Double Acting 3-Piece
Action: Double ActingActuation: PneumaticSize: 3/4"
from $45.90Amazon $45.90 -
4 Port Open PEX Manifold, 4 Outlet PEX A Multiport Tee
Outlets: 4Ports: 4
-
5 GPM Brass Flow Control Valve Assembly
Connection Size: 63/64"-20 UNSFlow Rate: 0.50 gpm
-
5 Way 2 Position Electric Solenoid Valve
Actuation: Electric SolenoidNumber of Positions: 2Number of Ways: 5
-
5-Way & 2-Position Air Valve: Pneumatic Actuator
Cubic Feet per Minute: 52.98Maximum Working Pressure: null PSIPneumatic Valve Type: Five-WayPositions: Two-PositionThread Size: 3/8"
-
5-Way & 2-Position Air Valve: Pneumatic Double Acting
Cubic Feet per Minute: 17.66Maximum Working Pressure: 113.000 PSIPositions: Two-PositionThread Size: 1/8"Valve Type: Five-Way
-
5-Way & 2-Position Air Valve: Toggle & Manual Actuator
Cubic Feet per Minute: 9.00Maximum Working Pressure: 127.980 PSIPositions: Two-PositionThread Size: 1/8"Valve Type: Five-Way
-
5/2 Double Control Pneumatic Valve
Control Type: Double Control
-
5/2 Way Solenoid Valve
Positions: 2Ways: 4
-
5/2-Way Double Solenoid Pneumatic Control Valve Sub-Base Mount
Ports: 5Ways/Positions: 5/2
-
5/2-Way Double Solenoid Pneumatic Directional Valve
Port Size: 1/8"Voltage: 24V DCWays/Positions: 5/2
-
5/2-Way Solenoid Valve
Configuration: 5 port, 2 wayVoltage: 120 VAC
-
5/2-Way Solenoid Valve
Type: single solenoid (monostable)Voltage: 24VDC
-
6 Valve Ports, Side-Ported Body, Manifold Kit
Valve Ports: 6
-
AV25 Stainless Steel Air Valve 1/4" Pipe Thread
Pipe Thread: 1/4"
-
-
from $15.09Amazon $15.09 -
from $213.99Zoro $213.99 -
Air Pilot Valve
Actuation: Air PilotMaximum Operating Pressure: 0.7 MPaNumber of Ports: 5
-
Air Pilot Valve
Maximum Operating Pressure: 0.7 MPaPorts: 5
-
-
Air Quick Exhaust Valve, Aluminum Alloy G1
Connection: G1
-
-
-
-
-
About pneumatic valves
Pneumatic valves regulate the flow and pressure of compressed air within a system, controlling actuators, cylinders, and other pneumatic components. Key types include solenoid valves, which use an electrical signal to actuate a spool or poppet; manual valves, operated by levers, pushbuttons, or rotary mechanisms; check valves, which permit flow in one direction only; and flow-control valves, designed to meter the rate of air flow. Manifold valves consolidate multiple valve functions into a single block, simplifying plumbing and reducing space requirements. Selection criteria typically involve port size (e.g., 1/8 NPT, G1/4), operating pressure range (e.g., 0.15 to 1.0 MPa), flow rate (e.g., Cv factor or L/min), and actuation method (e.g., 24V DC solenoid, detented lever). Spool configurations are often designated by the number of ways and positions (e.g., 5/2-way, 3/2-way normally closed). Common body materials include aluminum, brass, and engineering plastics, with seals typically made from NBR, FKM, or EPDM, chosen based on operating temperature and media compatibility.
How to choose
Choosing a pneumatic valve starts with defining its function: isolation, directional control, flow regulation, or pressure control. For directional control, determine the required number of ways (e.g., 2-way for on/off, 3-way for single-acting cylinders, 5-way for double-acting) and positions (e.g., 2-position, 3-position center closed). Next, specify the actuation method: electric (solenoid), manual, or pneumatic pilot. Consider the required flow rate (Cv value) and operating pressure range to ensure adequate performance. Finally, select the appropriate port size and thread type (e.g., NPT, G-thread) for system integration, balancing flow capacity with physical constraints.