Air Operated Double Diaphragm (AODD) Pump
Port Size: 1" NPT
-
1 HP 9.6 CFM 2-Stage HVAC Vacuum Pump
Flow Rate: 9.6 CFMHorsepower: 1 HPRPM: 1728 RPMStages: 2-Stage
-
1" Hose 1/7 HP 20GPM 12V DC High-Flow Gear Pump
Delivery Rate: 20 gpmHorsepower: 0.14 HPHose Size: 1 "Operating Pressure: 10 psiVoltage: 12V DC
-
1-1/2 HP 115/230V 1-Phase ODP Cast Iron Steel Rotary Gear Pump
Capacity: 24.8 gpmHorsepower: 1.5 HPPhase: 1-PhaseVoltage: 115/230V
-
1.5 CFM Vacuum Pump
Flow Rate: 1.5 CFM
-
1.5 HP Shallow Well Pump
Horsepower: 1.5 HP
-
1.5" Chemical Resistant PP Double Air Diaphragm Pump
Port Size: 1.5"
-
1/2 HP Non-Submersible Portable Transfer Pump
Horsepower: 0.5 HP
-
1/3 HP 4 CFM Air Vacuum Pump
Flow Rate: 4 CFMHorsepower: 0.33 HP
-
1/4 HP 3.5 CFM Air Vacuum Pump
Flow Rate: 3.5 CFMHorsepower: 0.25 HP
-
1/5 HP 3.5 CFM AC Vacuum Pump, Single Stage Rotary Vane
Flow Rate: 3.5 CFMHorsepower: 0.2 HPStages: Single Stage
-
1/6 HP Plastic Submersible Utility Pump
Power: 1/6 HP
-
1/6 HP WaterBUG Submersible Utility Pump with Multi-Flo
Flow Rate: 1257 Gal/HourPower: 1/6 HPWater Removal Down To: 1/16 in
-
110-Volt 1/2 HP 5 CFM Dual Stage Rotary Vane HVAC Air Vacuum Pump
Flow Rate: 5 CFMHorsepower: 0.5 HPStages: Dual StageVoltage: 110V
-
115 / 230V 5.6 CFM Direct Drive Rotary Vane Pump
Flow Rate: 5.6 CFMVoltage: 115V / 230V
-
115V 2.8 CFM Direct Drive Rotary Vane Pump
Flow Rate: 2.8 CFMVoltage: 115V
-
115V 4.2 CFM Direct Drive Rotary Vane Pump
Flow Rate: 4.2 CFMVoltage: 115V
-
12V Self Priming Impeller Gear Pump
Flow Rate: 3.2 GPMVoltage: 12V
-
2.5 CFM 1/6 HP One Stage Vacuum Pump
Flow Rate: 2.5 CFMPower: 1/6 HPStages: 1Vacuum Down To: 75 micron
-
200W Electric Oil Water Pump
Lift: 10-20 mPower: 200 WRated Speed: 4500 RPMSuction: 3-6 mVoltage: 12V 24V 48V 220V
-
230 / 460V 5.6 CFM Direct Drive Rotary Vane Pump
Flow Rate: 5.6 CFMStages: Two-stageVoltage: 230 / 460V
-
260W Cordless Garden Water Pump
Flow Rate: 18-25 L/minPower: 260 WRange: 150 mSuction Lift: 4-5 m
-
3/4" Hose 1/7 HP 15GPM 24V DC Heavy Duty Gear Pump
Delivery Rate: 15 gpmHorsepower: 0.14 HPHose Size: 0.75 "Inlet Size: 1 "Nozzle Size: 0.75 "
-
3CFM 1/4HP 1-Stage Rotary Air Vacuum Pump
Flow Rate: 3 CFMHorsepower: 0.25 HPStages: 1
-
3V Mini Self-Priming Diaphragm Water Pump
Flow Rate: 300 mL/minSize: 17 mmVoltage: 3 V DC
-
4 CFM Vacuum Pump for AC System
Flow Rate: 4 CFMHorsepower: 0.25 HPVacuum Level: 5 Pa
-
4 HP Honda GX120 Engine Self-Priming Sludge Diaphragm Pump
Horsepower: 4 HP
-
4.5 CFM 1/3 HP AC Vacuum Pump
Flow Rate: 4.5 CFMHorsepower: 0.33 HP
-
48" Hose and Spout Oil and Anti-freeze Hand Lift Pump
Hose Length: 48 "
-
6 CFM Spark-Free 1/2 HP 110V Vacuum Pump
Capacity: 330 mlFlow Rate: 6 CFMHorsepower: 0.5 HPInlet Ports: 3Ultimate Vacuum: 75
-
7 CFM 1/2 HP Vacuum Pump
Flow Rate: 7 CFMHorsepower: 0.5 HP
-
-
Air Operated Double Diaphragm Pump
Max Temperature: 150 FNPT: 1/2"
-
Air Operated Double Diaphragm Pump
Inlet: 1-1/2 InchMaximum Pressure: 120 psiMaximum Temperature: 150 °FOperating Pressure: 29 to 115 PSI
-
Air Operated Double Diaphragm Pump
Flow Rate: 44 GPM
-
Air Pilot Type Process Pump
Discharge Rate: 1 to 20 l/min
About pumps
Pumps are mechanical devices designed to move fluids, whether liquids, gases, or slurries, by converting mechanical energy into hydraulic energy. They are broadly categorized by their operational principle into positive displacement and kinetic (dynamic) types. Positive displacement pumps, such as gear, diaphragm, and peristaltic pumps, trap a fixed volume of fluid and force it into the discharge pipe. Kinetic pumps, including centrifugal and axial-flow pumps, impart velocity to the fluid through an impeller, then convert that velocity into pressure. Key selection parameters include flow rate (typically in GPM or m³/hr), discharge pressure (PSI or bar), NPSH requirements, and fluid viscosity. Material compatibility is critical, with common construction materials including cast iron, stainless steel (304, 316L), bronze, and various polymers like PTFE or PVDF, chosen based on fluid corrosivity, temperature, and abrasiveness. Seal types, such as mechanical seals, packing, or sealless magnetic drive designs, are specified according to leakage tolerance and fluid characteristics. Drive mechanisms range from electric motors (AC/DC, single/three-phase) to pneumatic or hydraulic power sources, with considerations for RPM and power consumption (HP or kW). Connection types often conform to NPT, BSPT, or flange standards like ANSI B16.5.
How to choose
title: How to Choose a Pump
steps: What fluid is being pumped? Identify its viscosity, temperature, chemical compatibility, and presence of solids. This dictates material selection and pump type.
What flow rate (GPM/m³/hr) and discharge pressure (PSI/bar) are required? This defines the pump's hydraulic performance curve and motor sizing. Consider system head losses.
What is the available Net Positive Suction Head (NPSHa)? Compare this to the pump's NPSH required (NPSHr) to prevent cavitation. Evaluate suction lift or flooded suction conditions.
What power source is available (electric, pneumatic, hydraulic)? Specify voltage, phase, and frequency for electric motors, or air/fluid pressure for others. Consider hazardous area classifications (e.g., ATEX, NEMA).
What level of leakage is acceptable? Select between sealed (mechanical seals, packing) or sealless (magnetic drive, canned motor) designs based on fluid toxicity or value, and maintenance requirements.