Flow & Pressure Instruments
Gauges, transducers, flow meters and pressure switches.
Also searched as: pressure gaugeflow meterpressure transducerpressure switch
-
-
M12-4 pin Refrigerant Pressure Transducer 9-36VDC
Connector: M12-4 pinVoltage: 9-36VDC
-
-
-
Mechanical Pressure Control Switch
Function: ControlType: Mechanical
-
Mechanical Pressure Switch for Water Pump
Application: Water PumpType: Mechanical
-
Multi-Range Pressure Transducer, -5" Wc
Pressure Range: -5" WC
-
Multi-parameter LCD 360 Degree Adjustable Gauge Pressure Transmitter
Pressure Range: 100Pa~110MPa
-
-
NPT1/4 Pressure Transmitter Sensor 0-100psi 1000Psi to 4-20mA
Output: 4-20mA, 0-10VPressure Range: 0-100psiThread: NPT1/4
-
-
Panel Mounted Adjustable GPM/LPM Liquid Flow Meter
Measurement: GPM/LPM
-
-
Piezoresistive Pressure Transducer Pressure Sensor
Voltage: 3.3V, 5V, 12V DC
-
-
Pneumatic Flow Switch
Lead Wire Connection: 3mRated Pressure Range: -0.05 to 0.75 MPaTemperature Range: 0 to +50 °C
-
Pressure Flow Rate Temperature Gauge
Flow Rate: 0-13 GPMPressure Range: 0-160 PSI
-
Pressure Gauge
Connection: 1/4" MNPTDial Diameter: 4-1/2"Pressure Range: 0 to 200 psi
-
Pressure Gauge
Connection: 1/4 in NPTDial Size: 2-1/2 inPressure Range: 0 to 15000 psi
-
Pressure Gauge
Pressure Range: 30 psiSize: 1.38"
-
Pressure Gauge
Overall Height: 66 mmOverall Length: 148 mmOverall Width: 101 mmWeight: 1.95 lbs
-
Pressure Gauge with Double Scale Displays
Connection: 1/4" male center rearDiameter: 63 mm
-
Pressure Gauge, 0-160psi/0-10bar
Connection Size: 1/8" NPTDial Size: 40 mmPressure Range: 0-160 psi / 0-10 bar
-
Pressure Gauge, 1-1/2" Dial, 1/8" Thread, Lower Mount
Dial Size: 1-1/2"Gauge Type: General PurposeMount: LowerPressure Range: 0 to 60Thread Size: 1/8"
-
-
Pressure Sensor
Output: I2cPower Supply: 3.3V DC
-
Pressure Sensor
Pressure Range: up to 2,000 psi
-
-
-
Pressure Switch
Pressure Range: 2.9 - 232 psiProcess Connection: 1/4 BSPP Female Thread
-
Pressure Switch
Connection: 1/4" FNPSFactory On/Off Setting: 80/100 psiPorts: 4Range: 20 to 100 psiType: Standard, DPST
-
Pressure Switch
Pressure Setting: 30 psi 50 psi
-
Pressure Switch
Pressure Setting: 30/50 PSI
-
Pressure Switch
Pressure Setting: 40/60 psi
-
Pressure Switch
Pressure Setting: 30/50
-
Pressure Switch
Pressure Setting: 145 - 175 psi
About flow & pressure instruments
Flow and pressure instruments are essential for monitoring and controlling fluid dynamics in industrial and laboratory settings. This category encompasses devices such as gauges, transducers, flow meters, and pressure switches. Pressure gauges provide local, visual indication of pressure and are available in mechanical (e.g., Bourdon tube, diaphragm, bellows) and digital formats, typically with accuracy classes ranging from 0.05% to 5% of full scale. Common connection types include NPT, BSP, and G threads, with sizes from 1/8" to 1". Materials such as stainless steel, brass, and Monel are selected based on media compatibility and operating environment. Pressure transducers convert pressure into an electrical signal (e.g., 4-20mA, 0-10V), offering higher precision and integration with control systems, with ranges spanning from vacuum to 100,000 psi. Flow meters measure the rate of fluid movement, utilizing principles such as differential pressure (orifice plates, Venturi tubes), electromagnetic, ultrasonic, Coriolis, and turbine. Selection depends on fluid properties, required accuracy (typically 0.5% to 5% of reading), and pipe size (from fractional inches to several feet). Pressure switches provide a discrete output when a set pressure threshold is crossed, available in adjustable or fixed setpoint configurations, often with SPDT or DPDT contacts and NEMA ratings for environmental protection.
How to choose
When selecting flow and pressure instruments, first define the fluid type and its properties, such as viscosity, temperature, and corrosivity, to determine compatible wetted materials. Next, establish the required measurement range and accuracy, which dictates the sensor technology (e.g., Bourdon tube for general indication, Coriolis for high-accuracy mass flow). Then, consider the output requirements: local display for gauges, analog/digital signals for transducers/flow meters, or discrete switching for pressure switches. Finally, evaluate the environmental conditions, including ambient temperature, vibration, and hazardous area classifications (e.g., ATEX, UL), to ensure appropriate housing and sealing, along with process connection type and size.