Circuit Protection
Fuses, breakers, holders, surge suppressors and disconnects.
Also searched as: fusescircuit breakerfuse holdersurge protectordisconnect
-
Hardwired Surge Protector DIN Rail Mount
Surge Protection Capacity: 50 kAVoltage: 240 VAC
-
Heavy Duty Wiring Surge Protector with LED Display
Surge Protection: 140 Joules
-
High Voltage Surge Protector SPD-PV series
Working Voltage: 500V, 800V, 1000V
-
Hospital-Grade Surge Protector with 6 Hospital-Grade Outlets
Cord Length: 10 ftJoules: 1050Outlets: 6
-
In-Line Fuse Holder 2AG 5X20MM
Fuse Size: 5x20mmFuse Type: 2AG
-
In-Line Fuse Holder w/ Wire Loop Leads and Fuse
Amperage: 30 AVoltage: 32 V
-
In-line Fuse Holder
Fuse Type: Maxi-fuseMax Amperage: 80AWire Gauge: 4 or 8 gauge
-
Industrial Miniature Circuit Breaker, 6 AWG, 30 A, 277/480 AC, 2 Pole
Amperage: 30 APoles: 2Voltage: 277/480 ACWire Size: 6 AWG
-
-
Inline Fuse Holder
Voltage: 12VWire Gauge: 12 AWG
-
Inline Fuse Holder
Fuse Type: ATC/ATOMax Amperage: 40AWire Gauge: 10 AWG
-
Inline Fuse Holder
Fuse Type: ATC/ATO BladeWire Gauge: 16 AWG
-
Inline Fuse Holder
Fuse Type: ATC/ATOWire Gauge: 12 AWGWire Length: 8.7 inches
-
Inline Fuse Holder Mini Waterproof Automotive
Rated Current: 5 ARated Voltage: 32 VDC
-
Inline Fuse Holder for 5x20mm Fuses
Fuse Size: 5x20mm
-
Inline Fuse Holder for ATO/ATC Blade Fuses
Current Rating: 30 AFuse Type: ATO/ATC Blade
-
Isobar Surge Protector
Amperage: 97000 ACord Length: 6'Joule Rating: 3330 JOutlets: 6
-
-
Jcase FMX Low Profile Fuses Assortment
Amperage: 20A, 30A, 40A, 50A, 60A
-
MEGA Fuse Block ANL Bolt-on Blade Fuse Holder
Current Rating: 80A 100A 125A 150A 175A 200A 250A 300AType: Flat
-
MINI Inline Fuse Holder
Amperage: 25-30 ANumber of Poles: 2Wire Gauge: 12 AWG
-
Maxi Car Fuse Holder Water-resistant
Max Current: 60AWire Gauge: 8 AWG 10 AWG
-
Maxi Inline Fuse Holder
Voltage: 24Vdc or lessWire Gauge: 8 Gauge
-
Medium Automotive Fuse Holder KCD3
Current Rating: 15APins: 2
-
Metal Double Fuse Holder Fuse Box Cover
Voltage Rating: 125 V
-
-
Mini Blade Fuse 25 Amp White Type ATM
Current Rating: 25 A
-
Mini Blade Fuse Box
Amperage: 2 AVoltage Rating: 32V AC/DC
-
Mini Circuit Breaker Switch
Type: Mini Circuit Breaker Switch
-
Mini Fuse 8.0000 A
Amperage: 8.0000 ABody Type: CartridgeFuse Type: MiniOverall Diameter: 6.00 mmOverall Length: 25.00 mm
-
Mini Fuse, 16.0000 A
Amperage: 16.0000 AFuse Type: Mini
-
Mini-ANL Blade Fuse Block
Voltage Range: 12 / 24 / 32 volts
-
Miniature Circuit Breaker
Amperage: 20 ANumber of Poles: 1Voltage: 240 V
-
-
Molded Case Circuit Breaker, 300-600 AC, 3 Pole
Poles: 3Voltage Rating: 300-600 AC
-
About circuit protection
Circuit protection devices safeguard electrical systems from overcurrents, short circuits, and voltage surges. This category encompasses fuses, circuit breakers, fuse holders, surge suppressors, and disconnect switches. Fuses are sacrificial devices containing a metallic wire or strip that melts and breaks the circuit when current exceeds a specified rating. Key parameters include current rating (Amperes), voltage rating (Volts AC/DC), breaking capacity (kA), and time-current characteristics (e.g., fast-acting, time-delay). Common fuse types include cartridge (e.g., UL Class CC, J, RK5, T), blade (automotive), and surface-mount (SMD) fuses. Circuit breakers are resettable protective devices, available in thermal, magnetic, or thermomagnetic trip mechanisms. Specifications include current rating, voltage rating, number of poles, interrupt rating, and trip curve (e.g., B, C, D for IEC). Fuse holders are designed for specific fuse sizes and types, rated by current and voltage, and come in panel mount, PCB mount, or in-line configurations. Surge suppressors, or transient voltage surge suppressors (TVSS), protect against voltage spikes, characterized by clamping voltage, energy absorption (Joules), and response time. Disconnect switches isolate power, with ratings for current, voltage, and sometimes horsepower, and can be fused or non-fused, often with NEMA enclosure ratings for environmental protection.
How to choose
When selecting circuit protection, first determine the required current and voltage ratings of the circuit to be protected. Second, identify the fault current capacity of the system to ensure the chosen device has an adequate interrupt or breaking capacity. Third, consider the desired response time to overcurrents; fast-acting fuses protect sensitive electronics, while time-delay fuses accommodate inrush currents. Fourth, evaluate environmental conditions and mounting requirements, selecting appropriate enclosure ratings (e.g., NEMA 4X for harsh environments) and mounting styles (e.g., DIN rail, panel mount, PCB). Finally, decide between resettable circuit breakers for convenience or sacrificial fuses for precise, single-use protection, weighing maintenance against protection specificity.