Terminal Blocks & Blocks
DIN-rail terminals, barrier strips, distribution and grounding.
Also searched as: terminal blockdin terminalbarrier stripground bar
-
1.5mm Gary Spring DIN Rail Terminal Blocks
Size: 1.5 mm
-
10 Circuit Terminal Block Strip
Circuits: 10
-
10 Gang Terminal Block Assembly RAAK6N21-10, 8-24 AWG, 50A, 300VAC UL
Current: 50AVoltage: 300VACWire Gauge: 8-24 AWG
from $27.08Zoro $27.08 -
12 AWG 5.2mm Blue DIN Rail Mount Terminal Block
Color: BlueOverall Height: 1.870"Voltage: 600Width: 5.2mmWire Size: 12 AWG
-
12 AWG 5.2mm White DIN Rail Mount Terminal Block
Amperage: 20 AColor: WhiteType: Terminal BlockVoltage: 600 VWire Size: 26 AWG - 12 AWG
-
12 AWG 5.2mm Yellow DIN Rail Mount Terminal Block
Amps: 20Color: YellowOverall Height: 1.870"Overall Length: 1.850"Overall Width: 0.100"
-
12 Poles, 600 Volt, 60 Amp, -40 to 266°F, Polyester Thermoplastic Multipole Terminal Block
Amperage: 60 AmpMounting Type: DIN RailOperating Temperature: -40 to 275°FOperating Temperature Range: -40 to 266°FPoles: 12
-
12 Way Copper Screw Terminal Strip
Amperage: 35APositions: 12Voltage: 600V
-
14 Terminal Ground Bar
Number of Circuits: 20Terminals: 14
-
15 AWG - 2 AWG 16mm Blue DIN Rail Mount Terminal Block
Amps: 150Color: BlueOverall Height: 2.590"Overall Length: 2.370"Voltage: 600
-
2 Position 1 Level DIN Rail Terminal Block
Size: 2.5 mm
-
2.5 mm Spring Terminal Blocks
Size: 2.5 mm
-
2.5mm Terminal Blocks for DIN Rail
Wire Gauge: 2.5mm
-
207 Din Rail Terminal Block - Modular 2 Lines 7 Ways
Lines: 2Ways: 7
from $1.20Alibaba $1.20 -
3 Pole DIN Rail and Bolt On Screw Terminal IEC Contactor
Mounting Type: DIN Rail and Bolt OnPoles: 3Voltage: 600V AC / 220V DC
-
35MM Screw Type DIN Rail Terminal Block
Mounting: 35MM DIN Rail
-
35mm DIN Rail Screwless Type Terminal Block End Stop
Height: 1.25"Length: 1.50"Mounting Type: DIN RailType: ScrewlessWidth: 0.25"
-
5 Pin 9.5mm Barrier 300V 3A Terminal Block Strip
Current: 3APins: 5Pitch: 9.5mmVoltage: 300V
from $0.15Alibaba $0.15 -
6 AWG 10.2mm Gray DIN Rail Mount Terminal Block
Amps: 65 AColor: GrayVoltage: 600 VWire Size: 20 AWG - 6 AWG
-
6 AWG 10.2mm Yellow DIN Rail Mount Terminal Block
Amps: 65Color: YellowOverall Height: 1.870"Voltage: 600Width: 10.2mm
-
6 Positions Terminal Bus Bar
Positions: 6
-
6+2 Holes Pure Copper Ground Bar Bus
Holes: 6+2
-
-
8 Position Terminal Block
Positions: 8
-
8 Way Terminal Block Bus Bar
Ways: 8
-
8.2mm DIN Rail Mount Terminal Block
Overall Height: 2.240"Overall Length: 1.850"Overall Width: 0.240"Torque: 5.3 - 7.1Voltage: 600
-
-
Barrier Block Connector Screws with Captive Plate
Circuits: 8Pitch: 0.375" (9.53mm)
-
Barrier Screw Terminal Block Wire
Current Rating: 15ARows: DualVoltage Rating: 600V
-
Barrier Strip
Height: 0.62 inchLength: 4.63 inchVoltage: 300 V AC
-
Barrier Strip Connector
Circuits: 2Pitch: 0.438"
-
-
Barrier Strip Terminal Block
Center Space: 7.62 mmWire Range: 22-14AWG
-
Barrier Strip, 12 Poles
Poles: 12Wire Size: 20 AWG – 8 AWG
-
Barrier Terminal Block Strip Zb35 Right Angle 8.25mm
Rated Current: 24ARated Voltage: 300VShape: RectangleWire Range: 24-18AWG 2.5mm²
-
Barrier Terminal Strip
Wire Size: 10 AWG
About terminal blocks & blocks
Terminal blocks and barrier strips provide a secure, organized method for connecting electrical wires within control panels, machinery, and various electronic assemblies. DIN-rail mount terminal blocks, such as feed-through, ground, and disconnect types, are common for industrial control applications, offering modularity and ease of installation on standard 35mm or 15mm DIN rails. Barrier strips, characterized by their screw terminals separated by insulating barriers, are frequently used for lower voltage applications or where individual wire termination is preferred. Distribution blocks facilitate power distribution from a single input to multiple outputs, often featuring multiple poles and varying current ratings. Grounding blocks ensure a reliable earth connection for safety and EMI reduction. Selection criteria include current rating (Amperes), voltage rating (Volts), wire gauge compatibility (AWG or mm²), number of positions/poles, and terminal type (screw clamp, spring clamp, push-in). Materials typically include polyamide (PA66) or melamine for insulation, with conductive parts made from nickel-plated brass, copper, or steel, ensuring robust electrical and mechanical performance. Dimensions, such as pitch and overall footprint, are critical for panel layout.
How to choose
When selecting terminal blocks, first determine the required current and voltage ratings to match application demands. Second, identify the wire gauge(s) to be terminated, which dictates the appropriate terminal size and connection method (e.g., screw, spring, push-in). Third, consider the mounting preference: DIN-rail for modularity and industrial standards, or panel/surface mount for barrier strips. Fourth, specify the number of poles or positions needed for each connection point. Finally, evaluate any special functions required, such as grounding, fused, or disconnect blocks, which add specific capabilities at the expense of footprint and cost.