HVAC & Filtration
Air filters, ducting, blowers, dust collection and extraction.
Also searched as: air filterhepadust collectionductingfume extractor
-
2-Stage Dust Collection Hood
Stages: 2
-
Ducting
Diameter: 12 inchLength: 25 feet
-
Ducting Hose
ID: 4 inchLength: 50 ft
-
Dust Collection Bag Assembly, HEPA
Filtration Type: HEPAOverall Width: 12 inQuantity: 10
-
Dust Collection Fittings Network
Diameter: 4 in
-
-
Dust-Collection Attachment, SDS-Plus
Number of Pieces: 5
-
Flexible Aluminum Ducting
Length: 8 ftWidth: 4 inch
-
Fume Extractor with 4 inch Inlet
Arms: DualCFM: 800Free Air CFM: 1.00Inlet Diameter: 4 inch
-
Fume Extractor, Series 100
Amperage: 20 AFrequency: 60 HzMax Air Flow: 1200 cfmMotor Horsepower: 1.5 hpSeries: 100
-
Fume/Smoke Collector
Dimensions: 74x33.5 inchFilter MERV Rating: 15Input Voltage: 480V ACMax Air Flow: 1500 cfmMotor Horsepower: 2 hp
-
Industrial Ducting Hose
ID: 3 inchLength: 50 ftMax. Pressure: 29 psiVacuum Rating: 28.00" Hg
-
Pleated Air Filter
Size: 24x12x4
-
Portable Laser Fume Extractor
Blowers: 1Filtration: 3 stage HEPA
-
Replacement Aluminum Range Filters
Dimensions: 3-1/2 X 14-1/2 X 3/8 inches
-
Rigid Cell Air Filter
Size: 12W x 24H x 12D
-
Washable Aluminum HVAC Metal Mesh Air Filter
Nominal Size: 20 x 20 x 1
About hvac & filtration
HVAC & Filtration encompasses components used for air quality control and movement within industrial, commercial, and residential settings. Key components include air filters, which range from MERV 8 pleated filters for general ventilation to HEPA (High-Efficiency Particulate Air) filters for critical environments, rated for 99.97% efficiency at 0.3 microns. Ducting, available in rigid spiral-wound galvanized steel, flexible aluminum foil, or insulated polyester, is specified by diameter (e.g., 6-inch, 12-inch) and static pressure rating. Blowers and fans, such as centrifugal or axial types, are selected based on airflow (CFM - cubic feet per minute) and static pressure requirements, often detailed on fan curves. Dust collection systems integrate hoods, ductwork, cyclonic separators, and baghouses to capture airborne particulates. Fume extractors, often localized, utilize activated carbon filters or HEPA filters to remove gaseous contaminants and fine particulates. Material selection for filters includes fiberglass, synthetic media, and activated carbon, while ducting materials are chosen for corrosion resistance, temperature tolerance, and fire ratings. System design considers air change rates, contaminant types, and regulatory compliance.
How to choose
When selecting HVAC & Filtration components, first define the application's air quality requirements: particulate size and concentration, or gaseous contaminants. This determines the necessary filtration efficiency (e.g., MERV rating, HEPA, activated carbon). Second, calculate the required airflow (CFM) based on room volume and desired air changes per hour. This dictates blower size and ducting dimensions. Third, assess static pressure losses across the system, including filters, duct runs, and bends, to ensure the selected blower can overcome system resistance. Finally, consider material compatibility for temperature, chemical exposure, and fire safety ratings, particularly for ducting and filter media.