HVAC & Filtration
Air filters, ducting, blowers, dust collection and extraction.
Also searched as: air filterhepadust collectionductingfume extractor
-
Pleated Air Filter, MERV 8
Depth: 1 inLength: 25 inMERV Rating: 8Width: 16 in
-
Pleated Air Filter, MERV 8
Depth: 2 inLength: 20 inMERV Rating: 8Width: 16 in
-
Pleated Air Filter, MERV 8
Depth: 2 inLength: 24 inMERV Rating: 8Width: 20 in
-
Pleated HVAC AC Furnace Air Filter
Dimensions: 20 x 23 x 1 inchFPR Rating: 5MERV Rating: 8
-
Pleated HVAC AC Furnace Air Filter
Dimensions: 14 x 24 x 1 inchFPR Rating: 5MERV Rating: 8
-
Pleated HVAC AC Furnace Air Filter
Dimensions: 20 x 25 x 4 inchFPR Rating: 5MERV Rating: 8
-
Pleated HVAC AC Furnace Air Filter
Dimensions: 20 x 30 x 1 inchFPR Rating: 5MERV Rating: 8
-
-
Portable Dust Collector for Wood Working
Air Flow: 1925 CFMStatic Pressure: 9.26 in WaterVoltage: 230 Volt
-
Portable Dust Collector with Filter
Phase: SingleVoltage: 230 Volt
-
Portable Fume Extractor
Flow Rate: 750 cfm
-
Portable Fume Extractor
Airflow: 875 cfm
-
Portable Fume Extractor
Air Flow: 500 CFMHorsepower: 0.5 hpInput Voltage: 120 VPhase: Single
-
Portable Fume Extractor
Arm Length: 12 ftFlow Rate: 875 cfm
-
Portable Fume Extractor
Flow Rate: 115 cfm
-
Portable Fume Extractor
Power: 45 W
-
-
Portable Fume Extractor with Articulating Arm
Airflow: 875 cfmArm Length: 10 ft
-
Portable Fume Extractor, HEPA Filter
Air Flow: 750 CFMAmperage: 12.5 AArm Length: 10 ftFilter Efficiency: 99.97%Model: 750
-
Portable Laser Fume Extractor
Blowers: 1Filtration: 3 stage HEPA
-
-
-
Premium H13 HEPA Air Filter
HEPA Grade: H13
-
Primary Air Filter
Height: 4.5"Inner Diameter: 3.5"Outer Diameter: 5.50"
-
Primary Air Filter
Height: 24.5"Inner Diameter: 7.5"Outer Diameter: 12"
-
PureFlo ESM + HEPA Particulate Filter
Filter Type: HEPA
-
Replacement Aluminum Range Filters
Dimensions: 3-1/2 X 14-1/2 X 3/8 inches
-
Reusable HVAC Air Filter
Dimensions: 16-3/8 x 21-1/2 x 1 inch
-
Rigid Cell Air Filter
Size: 12W x 24H x 12D
-
Semi-Rigid Flexible Aluminum Duct
Diameter: 6 inLength: 8 ft
-
Small Portable Fine Dust Collection Wood Chip Vacuum
Size: 410x410x700 mm
-
Smart Room Desktop True HEPA Air Purifier
HEPA Grade: HEPA 13
-
Solder Fume Extractor
Airflow: 168m³/hPower: 80W
-
Solder Fume Extractor
Power: 30 W
-
Solder Fume Extractor for Laser Cutter
Airflow: 310 m³/hFilters: 8Power: 200 W
-
Solder Fume Extractor, 100 Watt, 240 m³/h, 3-stage filter system
Airflow: 240 m³/hFilter stages: 3Power: 100 WPurification rate: 99.99 %
About hvac & filtration
HVAC & Filtration encompasses components used for air quality control and movement within industrial, commercial, and residential settings. Key components include air filters, which range from MERV 8 pleated filters for general ventilation to HEPA (High-Efficiency Particulate Air) filters for critical environments, rated for 99.97% efficiency at 0.3 microns. Ducting, available in rigid spiral-wound galvanized steel, flexible aluminum foil, or insulated polyester, is specified by diameter (e.g., 6-inch, 12-inch) and static pressure rating. Blowers and fans, such as centrifugal or axial types, are selected based on airflow (CFM - cubic feet per minute) and static pressure requirements, often detailed on fan curves. Dust collection systems integrate hoods, ductwork, cyclonic separators, and baghouses to capture airborne particulates. Fume extractors, often localized, utilize activated carbon filters or HEPA filters to remove gaseous contaminants and fine particulates. Material selection for filters includes fiberglass, synthetic media, and activated carbon, while ducting materials are chosen for corrosion resistance, temperature tolerance, and fire ratings. System design considers air change rates, contaminant types, and regulatory compliance.
How to choose
When selecting HVAC & Filtration components, first define the application's air quality requirements: particulate size and concentration, or gaseous contaminants. This determines the necessary filtration efficiency (e.g., MERV rating, HEPA, activated carbon). Second, calculate the required airflow (CFM) based on room volume and desired air changes per hour. This dictates blower size and ducting dimensions. Third, assess static pressure losses across the system, including filters, duct runs, and bends, to ensure the selected blower can overcome system resistance. Finally, consider material compatibility for temperature, chemical exposure, and fire safety ratings, particularly for ducting and filter media.