HVAC & Filtration
Air filters, ducting, blowers, dust collection and extraction.
Also searched as: air filterhepadust collectionductingfume extractor
-
1/2" NPT .01 Micron Coalescing Air Filter
Micron Rating: 0.01 micronNPT: 1/2"
-
150W Solder Fume Smoke Extractor, 3-Stage Filters, 332 m³/h
Airflow: 332 m³/hFilter stages: 3Power: 150 W
-
19" W x 14" H x 3" D H13 HEPA Carbon / Pre-Filter HEPA Air Filter
Depth: 3"Efficiency: >99.97%HEPA Grade: H13Height: 14"Maximum Velocity: 300 cfm
-
2-Stage Dust Collection Hood
Stages: 2
-
23" x 23" x 12" BIOMAX 99.97% Efficiency .3 Micron Wood HEPA Air Filter
Depth: 12"Efficiency: 99.97%Length: 23"Maximum Operating Temperature: 180°FMaximum Velocity: 500 fpm
-
24" x 24" x 12" BIOMAX DTF 99.97% Efficiency Synthetic HEPA Filter
Depth: 12"Efficiency: 99.97%Length: 48"Width: 24"
-
3/8" NPT Polycarbonate Bowl HEPA Paper Felt Intermediate Modular Air Filter
Bowl Size: 1.90 ozFilter Micron Size: 5 MicronFlow Rate: 150 scfmLength: 2.874"NPT: 3/8"
-
330-Watt Solder Fume Extractor, 270 CFM
Airflow: 270 CFMPower: 330 W
-
90-DEGREE BENT TUBING FOR WATER FILTRATION SYSTEM
Angle: 90 Degree
-
ABS Blast Gate
Size: 3 in
-
AF Modular Style Air Filter, 1/2 NPT Ports, Metal Bowl, Automatic (Normally Closed) Drain
Bowl Material: MetalDrain Type: Automatic (Normally Closed)Port Size: 1/2 NPTWeight: 1.49 lbs
-
AW FILTER/REGULATOR, MODULAR F.R.L.
Port Size: 1/2 BSPTProof Pressure: 218 psiTemperature Range: 23 to 140 °F
-
AW FILTER/REGULATOR, MODULAR F.R.L. with 1/2 BSPT Port Size
Port Size: 1/2 BSPTPressure Range: 7 to 101 psi
-
AW Filter/Regulator
Maximum Operating Pressure: 145 psiOperating Temperature Range: 23 to 140 °FProof Pressure: 218 psiSet Pressure Range: 7 to 123 psi
-
-
Air Filter
Dimensions: 10 x 24 x 1 inchFPR Rating: 10MERV Rating: 13
-
Air Filter AF30-03-A
Bowl Drain Method: ManualBowl Material: PolycarbonatePort Size: 3/8 BSPTWeight: 0.18 kg
-
Air Filter MERV 13 Pleated HVAC AC 24x36x1
Dimensions: 24x36x1 inchMERV Rating: 13
-
Air Filter for AC Furnace and HVAC
Dimensions: 20 x 20 x 1 inchMERV Rating: 11
-
-
-
Air Ventilator Flexible Ducting
Diameter: 20 In.Length: 25 Ft.
-
-
All in One HVAC Filtration Mist Eliminator
Efficiency: 98 %
-
Aluminum Flexible Ducting
Diameter: 4-InchLength: 8FT
-
-
Blower Ducting
Diameter: 12 inchLength: 15 ft
-
Car Heater Ducting Reducer Exhaust Pipe Hose
Diameter: 60/75/90 mm
-
Commercial Mall HVAC Filtration System
Purification efficiency: 95 %
-
Dryer Vent Hose
Diameter: 4 inch
-
Ducting
Diameter: 26 inLength: 25 ft
-
Ducting
Diameter: 12 inchLength: 25 feet
-
Ducting
Diameter: 26 inLength: 15 ft
-
Ducting Hose
ID: 4 inchLength: 50 ft
-
Dust Collection Attachment, 2-in-1 Vacuum
Hose Size: 1-1/4", 1-1/2", 1-7/8", 2-1/2"
-
Dust Collection Bag
Compatibility: 50617/54290/56303, 56332
About hvac & filtration
HVAC & Filtration encompasses components used for air quality control and movement within industrial, commercial, and residential settings. Key components include air filters, which range from MERV 8 pleated filters for general ventilation to HEPA (High-Efficiency Particulate Air) filters for critical environments, rated for 99.97% efficiency at 0.3 microns. Ducting, available in rigid spiral-wound galvanized steel, flexible aluminum foil, or insulated polyester, is specified by diameter (e.g., 6-inch, 12-inch) and static pressure rating. Blowers and fans, such as centrifugal or axial types, are selected based on airflow (CFM - cubic feet per minute) and static pressure requirements, often detailed on fan curves. Dust collection systems integrate hoods, ductwork, cyclonic separators, and baghouses to capture airborne particulates. Fume extractors, often localized, utilize activated carbon filters or HEPA filters to remove gaseous contaminants and fine particulates. Material selection for filters includes fiberglass, synthetic media, and activated carbon, while ducting materials are chosen for corrosion resistance, temperature tolerance, and fire ratings. System design considers air change rates, contaminant types, and regulatory compliance.
How to choose
When selecting HVAC & Filtration components, first define the application's air quality requirements: particulate size and concentration, or gaseous contaminants. This determines the necessary filtration efficiency (e.g., MERV rating, HEPA, activated carbon). Second, calculate the required airflow (CFM) based on room volume and desired air changes per hour. This dictates blower size and ducting dimensions. Third, assess static pressure losses across the system, including filters, duct runs, and bends, to ensure the selected blower can overcome system resistance. Finally, consider material compatibility for temperature, chemical exposure, and fire safety ratings, particularly for ducting and filter media.