Machine Safety
Light curtains, E-stops, safety relays, interlocks and guarding.
Also searched as: light curtaine stopsafety relayinterlock switchmachine guard
-
10250T Illuminated Red Mushroom Fully Assembled Emergency Stop Pushbutton
Voltage: 600 V AC, 250 VDC
-
-
3-PHASE interlock switch with cap nut
Phase: 3-Phase
-
3P4W 100A 3PH 250V Gray/Blue IEC Unfused Mechanical Circuit-Lock Interlock
Amperage: 100 AColor: Gray/BluePhase: 3PHPoles: 3Standard: IEC
-
3P4W 100A 3PH 480V Gray/Red IEC Unfused Mechanical Circuit-Lock Interlock
Amperage: 100 AColor: Gray/RedPhase: 3PHPoles: 3Standard: IEC
-
Aluminum Machine Safety Sign
Height: 7 inchWidth: 10 inch
-
C22 Series Non-Illuminated Red Mushroom Fully Assembled Emergency Stop Pushbutton
Voltage: 250 V AC, 220 V DC
-
-
-
M22 Series Non-Illuminated Red Mushroom Momentary Emergency Stop Pushbutton
Voltage: 500 V AC, 200 VDC
-
M22 Series Non-Illuminated Red Mushroom Momentary Fully Assembled Emergency Stop Pushbutton
Voltage: 500 V AC, 200 VDC
-
PLUNGER INTERLOCK SWITCH, 15 AMP
Amperage: 15 A
-
Plastic Safety Training Mandatory Sign
Height: 10 inchWidth: 14 inch
-
Polyamide PA66-GF25 Safety Interlock Limit Switch
Connection Type: 1/2" Conduit OpeningContact Rating: 6A at 230 VAC, 0.5ALength: 1.22"Range: -13°F - 158°F
-
Polyamide Safety Interlock Limit Switch
Contact Rating: 300 mA at 24 VDCLength: 5"Temperature Range: 14°F - 131°F
About machine safety
Machine safety components are critical for protecting personnel and equipment in industrial environments. This category includes light curtains (safety light screens), emergency stop (E-stop) devices, safety relays, interlock switches, and machine guarding. Light curtains, typically Type 2 or Type 4 per IEC 61496, create a protective field using an emitter and receiver, with resolution (e.g., 14mm for finger protection, 30mm for hand protection) and protected height being key specifications. E-stops are push-button or pull-cord devices designed for immediate machine shutdown, often featuring twist-to-release or key-release mechanisms, and contact configurations like 1NC/1NO or 2NC. Safety relays (e.g., PLe, SIL 3 rated) monitor safety functions and provide redundant outputs, with common types including emergency stop relays, guard interlock relays, and two-hand control relays. Interlock switches prevent machine operation when guards are open, available in mechanical (tongue/key), magnetic, and RFID-coded variants, with locking force (e.g., 1300N, 2500N) and IP rating (e.g., IP67) being important. Machine guarding encompasses physical barriers such as wire mesh panels, polycarbonate sheets, and aluminum profiles, selected based on impact resistance, visibility requirements, and mounting options.
How to choose
When selecting machine safety components, first determine the required Performance Level (PL) per ISO 13849-1 or Safety Integrity Level (SIL) per IEC 62061 for the application. Next, identify the specific hazard and the necessary protective function (e.g., presence detection, emergency stop, guard interlocking). For presence detection, choose a light curtain based on resolution (finger, hand, body) and protected height. For E-stops, select based on actuation method (push-button, pull-cord) and contact configuration. For interlocks, consider the guard type, locking requirement, and actuator type (tongue, RFID). Finally, select a safety relay or safety PLC capable of achieving the required PL/SIL, ensuring compatibility with all connected safety devices and monitoring functions.